Flourescence Spectrophotometer (200-900nm)

SKU ML-FL96 Category

Flourescence Spectrophotometer (200-900nm)

Pack Size

1 No

The fluorescence spectrophotometer provides a precision analytical method with high sensitivity, selectivity, and a wide linear range of operating curves It is commonly used in medical analysis, biochemistry, pharmaceutical science, environmental monitoring and other industries. It is the instrument of choice in the field of trace analysis the emission monochromator adopts 1200 lines of diffraction grating. Its large aperture and aspherical reflector produce ultra-high sensitivity. The EX lamp adopts a long-life, cold light source LED that matches the center wavelength of 365nm, which is easy to maintain and has no thermal pollution. With automatic zeroing and automatic background deduction. With an interface, it is more convenient to transmit data, store, record, and draw standard working curves excellent quality and high safety, especially for education and laboratory. Eight levels of sensitivity adjustment, real-time fluorescence reading display accurately measure the small changes in the sample.

 

Model ML-FL93 ML-FL931 ML-FL96
Excitation Source 150W xenon lamp (Hamamatsu) 150W xenon lamp (Hamamatsu) 150W xenon lamp (Hamamatsu)
Excitation Wavelength 200nm-900nm 200nm-900nm 200nm-900nm
Emission Wavelength 200nm-900nm 200nm-900nm 200nm-900nm
Excitation Slit 1nm/2nm/5nm/10nm/20nm 1nm/2nm/5nm/10nm/20nm 1nm/2nm/5nm/10nm/20nm
Emission Slit 1nm/2nm/5nm/10nm/20nm 1nm/2nm/5nm/10nm/20nm 1nm/2nm/5nm/10nm/20nm
Wavelength Accuracy ±0.4nm ±0.4nm ±0.4nm
Wavelength Repeatability ?0.2nm ?0.2nm ?0.2nm
Signal-to-Noise Ratio S/N?350(P-P), S/N?1000(RMS) S/N?350(P-P), S/N?1000(RMS) S/N?350(P-P), S/N?1000(RMS)
Limit ?5×10-11 g/ml (Quinine Sulfate Solution) ?5×10-11 g/ml (Quinine Sulfate Solution) ?5×10-11 g/ml (Quinine Sulfate Solution)
Linearity ??0.995 ??0.995 ??0.995
Peak Repeatability ?1.5% ?1.5% ?1.5%
Wavelength Scan Speed Multi-speed Level, Maximum at 60000nm/min Multi-speed Level, Maximum at 60000nm/min Multi-speed Level, Maximum at 60000nm/min
Minimum Sample Size 0.5mL (Using a standard 10mm square sample cell) 0.5mL (Using a standard 10mm square sample cell) 0.5mL (Using a standard 10mm square sample cell)
Octave Filter Build in Octave filter Build in Octave filter Build in Octave filter
Photometric Quantity Range -19998 -19998 -19998
Response Time 0.02/0.1/0.5/1/2/4/8s, Auto adjust 0.02/0.1/0.5/1/2/4/8s, Auto adjust 0.02/0.1/0.5/1/2/4/8s, Auto adjust
Data Transportation USB 2.0 USB 2.0 USB 2.0
Power 200W 200W 200W
Power Source AC 220V/50Hz; 110V/60Hz AC 220V/50Hz; 110V/60Hz AC 220V/50Hz; 110V/60Hz
Size(W×D×H)(mm) 610×460×365 610×460×365 610×460×365
Shipping Size(W×D×H)(mm) 790x670x530 790x670x530 790x670x530
N.W./G.W. (kg) 21/47 21/47 21/47
Pack Size

1 No